Plumbing

On the Living Building Challenge ‘Red List’ are two products often used in conventional plumbing: Polyvinyl Chloride (PVC) and Lead (added). Our challenge here was to provide safe, affordable transport for our collected rainwater to Bull Street Terraces’ Taps.

(back to Materials)

Generally Accepted Process

PVC pipes

Chrome plated taps, fixtures and fittings.

Choices for Bull Street

Household plumbing – PEX pipe

Sewage pipes – HDPE or Vitrified Clay

Tap ware, shower head and toilet – Highest available WELS Star rating, manufactured in Australia. No lead in the taps chosen. Toilet with hand wash basin integrated into the cistern.

Taps, shower head and sink waste – unfinished brass.

Rain water tank – Atlantis Flo-Tank underground rain water collection system

Summary of Reasons

Polyvinyl Chloride (PVC) is a Red List material as it is toxic. PVC alternatives are available and are safer for the environment and us. Copper pipe plumbing is bacteriostatic, extremely durable and it resists temperatures changes well. Careful design will minimise runs reducing its material use and higher cost.

WELS is Australia’s water efficiency labelling scheme. Labels show a star rating and also a water consumption or water flow figure. The less water used, the higher the star rating. Tap ware, shower heads and toilets all have different maximum ratings. Tap ware can be a maximum of 6-stars, toilets can be a maximum of 5-stars and shower heads can be a maximum of 3-stars. (www.reece.com.au)

For the toilet to achieve the maximum 5 star rating the toilet has a hand wash basin integrated into the cistern. This saves water by allowing the same water to be used for two purposes. Fresh water is first used for hand washing and then flows into the cistern to ultimately flush the toilet.

Unfinished brass – chrome plating is a hazardous process and as such is heavily regulated. Lead Chromates and Barium Sulphate are two of the hazardous waste products of its production.

For the household plumbing we will use PEX pipe as it lasts longer than copper pipe, is better suited our situation – to rain water transportation, zincalume roofing, the plastic rain water tank and it is about one third of the cost of copper. The PEX/copper debate is documented at length in the Summary of Research below, it is not a clear cut choice and PEX pipe is not recyclable, so Crosbyarchitects will commit to reusing it in some way if it is ever removed from the building. Plant based HDPE is in development and will one day hopefully include plumbing pipe, this is an exciting progression as it is ultimately biodegradeable.

Design a system with as few joins as possible. Best practice – only joins at source and outlet. With minimum distances of water travel and no stagnant water. Consider pipe size/flow rate http://savegas.com/NewsArticles/HotWaterDist_Part1.pdf

Atlantis Flo-Tank underground rain water collection system as it is made from 100% recycled materials, predominantly recycled Polypropylene.

Summary of Research

ref: Plastic PVC Poisioning all living Things – YouTube 23.10.13

Published on Dec 29, 2012

The production of PVC is significantly more harmful to the environment than any other plastic, and not only because they are not recyclable. The process of making PVC plastics involves the fusing of chloride molecules — derived from petroleum — with heavy toxic metals like lead and cadmium. These toxins stabilize and plasticize PVC, but because of their use and the chemical properties of chlorine, byproducts of PVC production tend to be significantly more toxic and persistent in the ecosystem, traveling up the food chain to people. As the Center for Health, Environment, and Justice notes, PVC plastic is unique in its risks to health and environment. No other plastic contains as harmful substances, or as hazardous byproducts, as PVC plastic.

  • These toxins are building up in water, air and the food chain.
  • The results: severe health problems, including cancer, immune system damage, and hormone disruption.
  • No one can escape contamination.
  • Everyone, everywhere has measurable levels of chlorinated toxins in their bodies.

The PVC industry has been plagued by workers health and safety issues for decades. Many industries are aware of what PVC is doing to people but they are doing nothing to stop the use and production of PVC. When PVC is burned it gives off toxic hydrogen chloride gas, which turns into hydrochloric acid on contact with moisture within our lungs.

PVC alternatives are available and are safer for the environment and us.
http://www.acereport.org/pvc2.html
http://chej.org/

CHEJ (The Center for Health, Environment and Justice) coordinates a national campaign working to phase out PVC, the most dangerous plastic to our health and environment. In the past two years, we have successfully moved major Fortune 500 companies away from this unnecessary toxic plastic and towards safer and healthier alternatives.

Dow Chemical running from responsibility for poisoning around the world, including Plaquemine Parish, Louisiana:

http://bhopal.net/petition/applicatio

And then there are the chemicals added to PVC: Phthalates, a family of industrial chemicals used to soften PVC plastic and as solvents in cosmetics and other consumer products, can damage the liver, kidneys, lungs and reproductive system — particularly the developing testes — according to animal studies.

Medical devices made of flexible PVC, such as IV bags and tubing, can leach the phthalate DEHP into patients, resulting in some of the highest exposures to this toxic chemical.

Beauty Secrets: The Dangers Of Phthalates: Industry Spin vs. Fact:
http://www.ewg.org/node/8174
http://www.healthychild.org/issues/me

Deborah Cadbury, The Assault on the Male, BBC Horizon film:
http://www.youtube.com/watch?v=LkxIJJ
http://www.americanhealthstudies.org/

“The Gender Benders: Are environmental ‘hormones’ emasculating wildlife?,” first in a two part series, Janet Raloff, Science News, January 8, 1994, pg. 24 http://www.sciencenews.org/pages/sn_e
http://findarticles.com/p/articles/mi

Foreword to The Feminization of Nature: Our Future at Risk by Deborah Cadbury (London: Hamish Hamilton [Penguin], 1997) ISBN 0-14-026205-9 http://www.dhushara.com/book/renewal/

Multiple grassroots organizations of consumers have spoken out about the hazards of PVC plastic. These organizations include the Center for Health, Environment, and Justice, the Grassroots Recycling Network, Greenpeace, and even include a feature film on the dangers of PVC plastic, Blue Vinyl. Each organization has a compendium of resources and information about PVC plastic, and events and actions organized to halt the use of PVC plastic in everyday consumer items.

Opposition continues to grow to the use of this incredibly harmful material in our everyday lives.

http://www.noharm.org/us_canada/issue

75% of PVC is used in the building industry. (ref: Healthy Building Science healthybuildingscience.com 23.10.13)

Some common places where you should look to identify possible PVC:

  • Carpet backings
  • Flooring
  • Window Shading
  • Water Piping
  • Electrical Wiring
  • Roofing membranes
  • Window Assemblies

So what are our alternatives?

Suzette Jackson info@living-future.org.au

Copper (REF:Advantages and Disadvantages of Copper Pipe Plumbing D Swain 23.10.13)

When choosing the type of plumbing you want in your home, some of your options will include steel, plastic, and copper. Copper pipe plumbing has numerous advantages and disadvantages when compared to other materials. This article will discuss some of the advantages and disadvantages of copper pipe plumbing.

Advantages

One of the first advantages of copper pipe plumbing deals with installation. Copper is a relatively soft metal, so it can bend rather easily. Therefore, copper pipe plumbing can be installed using less fasteners and connectors. Since there will be less hardware used, it will be easier to install this type of plumbing.

Another advantage of copper pipe plumbing deals with the water supply. Bacteria can grow in other types of plumbing, especially plastic designs. Copper pipe plumbing is bacteriostatic. This means that bacteria can’t grow in the copper pipes. Also, there is no risk of lead poisoning as lead isn’t used during the manufacturing process.

Copper pipe plumbing is also extremely durable. Unlike designs made of steel, copper pipes will resist corrosion. They are also capable of withstanding ultraviolet rays unlike plastic designs. These characteristics make copper pipe plumbing ideal for outside uses such as in a sprinkler system.

One of the final advantages of copper pipe plumbing is that it resists temperatures changes well. If a fire ever occurs in your home, toxic gases will be released if you have CPVC, or plastic pipes. Copper pipe plumbing doesn’t burn, so it won’t release toxic gases.

Disadvantages

One of the most important disadvantages of copper pipe plumbing is the expense involved. Copper is a considerably more expensive material than plastic. Although the installation of copper pipe plumbing requires less hardware, it will still be more expensive to install.

Another disadvantage of copper pipe plumbing deals with water acidity. This type of plumbing is only suitable for water that has a pH between 6.5 and 8.5. Water that comes from a well may be too acidic for copper pipe plumbing. Therefore, it’s best to use this type of plumbing in locations that are supplied by the city water supply.

The following are two very informative answers on Green Building Advisor.com sourced on 23.10.13

PEX vs Copper

We are building a net zero energy home and need to decide to use PEX or Copper. What is the healthy option. will PEX leach from the plastic. and Copper leach lead from the joints? Would love to hear both the pros and cons for each application. Thank you, – Karen
ASKED BY KAREN MILLER
POSTED WED, 02/17/2010 – 17:05
TAGS: GREEN PRODUCTS AND MATERIALS

2 Answers

PEX will not leach bad chemicals into your plastic nor will copper leach lead from the solder, which is now lead free. PEX will be more durable than copper long term as it is more resistant to corrosion and freeze-thaw action. Copper’s vulnerability to corrosion will actually help reduce the corrosive effect of your water and will help prevent the water from corroding your faucets long term, (and faucets are still allowed to have lead in them, which is why it’s still a good idea to rinse the dust out of the tumbler with the first bit of water out of the faucet). It’s easier to replace corroded faucets than pipes and a corroded faucet may drip, but it won’t cause long term water damage the way a corroded pin hole in a copper pipe will. So, all things being equal you will be better off with PEX in the long run.

However the next question you will want to ask is “how do you design the piping system?” Gary Klein is the leading philosopher on this issue and the first of a four part series he has written is available to download here: http://savegas.com/NewsArticles/HotWaterDist_Part1.pdf to get part 2 just substitute a 2 for the one in the URL and 3 and 4 likewise.

The short answer is that water flows much differently in a pipe than most people think, it eddies at elbows and tees and the hot water doesn’t just push the cold water ahead of itself as it rushes down towards the sink but it swirls and mixes with the existing cold water in the pipe and comes out lukewarm at the faucet long before it gets hot and that all these issues are exacerbated by low flow fixtures.

So pipe lay-out and design is much more important than many (and the code) were aware. We want to remove every elbow we can from the hot water piping system, most especially elbows that are close to the water heater (do you have an elbow at the top of your tank? most likely.) We also want to get rid of “bull-headed tees” and only use tees that are the same diameter in the straight direction and smaller diameter in the side direction. Of course we want to use shorter pipe runs and insulate hot water pipes, never put them under a slab, and we should be questioning the diameter of every pipe.

If you need hot water in a primary bath for two sinks, a tub and a shower it is fair to ask how often more than one of these fixtures will be used at the same time and if they are all low flow except for the bathtub you may want to serve them with a half inch line or at least supply the tub with a dedicated half inch home run from the water heater and supply the rest of the fixtures with a dedicated half inch line… Think about it, plan it out, question assumptions but most especially don’t let the plumber “just do it to code” or you’ll be watching cold water run out of the hot water tap for a long time before you hop in that shower.

Gary has evolved greatly in the time since these articles were written and has gotten involved in the development of the Metlund D’mand recirculating hot water system (good) and Navien’s demand water heater (not a fan). I warn people about the flow rate related pressure drop problem with the Navien water heaters which is an issue for those of us who build luxury green homes and is why many of us have chosen to stick with the Rinnai and Quietside condensing demand water heaters.

But mostly I think we’ve stepped past one of the most elegant solutions which is to have a central solar/ demand water heater solution with small under counter or closet located electric hot water tanks in the remote bath rooms that just receive hot water from the central water heater and keep it from cooling down for no wait usage in that bathroom. It’s an in-expensive and effective solution. So long as you are able to provide the 1,500 watts those units draw from time to time to keep the water from cooling down.

Interesting anecdote about that though, I built a house a while back that was very spread out and the client called a year or so after moving in to say that the water heater wasn’t getting hot water to the primary bath for some reason. I stopped by to check it out and discovered that the 110 volt water heater had been wired to a 220 breaker and had most likely burned up the element the first time it was used but, because it was constantly being refreshed with hot water so long as people were living there, it never got cold until they went on vacation and they lived there for a year without knowing the auxiliary water heater was broken and had fast hot water all that time. I fixed it, but my point is that it probably doesn’t use much electricity if it works well when the breaker is popped

ANSWERED BY MICHAEL CHANDLER, GBA ADVISOR
Posted Wed, 02/17/2010 – 20:43

2. As with most building materials today, it’s not easy to determine the relative merits of copper and PEX for domestic water supply. There are significant benefits and liabilities, including deleterious health impacts of both. The following is a summary of the issues. My best advice at this point is to use copper for chlorinated water supplies and PEX for private wells, particularly with acidic water, or with ionic water softeners.

Copper is a naturally-occurring mineral with associated mining impacts, but it’s easily recyclable (and often contains a high recycled content), while cross-linked polyethylene is not.

Copper domestic water piping must be soldered with “lead-free” solder (no more than 0.2% lead) and fittings, except in CA and VT under new rules can contain up to 8% lead. Soldering flux is also toxic as well as corrosive to the copper. For this reason and because of galvanic and chemical reactions, copper is vulnerable to corrosion and pin-hole leaks. It is highly vulnerable to frost-breakage. Over time, copper pipes build up a layer of mineral deposits from hard water which constricts water flow and, along with internal burrs and irregularities, creates turbulence and noise. Water turbulence in pipes, often exacerbated by too-small diameter piping, causes increased dissolution of heavy metals such as lead and copper, particularly when water pH is less than 6.5 (acidic, as most water is today). Noise and water-hammer is exacerbated by rigid tubing, angular direction changes and high velocities due to narrow pipe.

Not only is dissolved lead a problem in domestic water systems, though largely mitigated since the lead ban in 1998, but dissolved copper has become increasingly recognized as a threat to both human health and the environment, limited by the EPA to 1.3 parts per million in domestic water supplies.

Copper dissolution occurs in new piping, and in piping carrying acidic water, soft water (low dissolved solids), or water with high dissolved oxygen. It is recommended that water sitting in copper supply pipes for more than 6 hours be flushed for 30 to 60 seconds before using for drinking or cooking, that hot water (more dissolved metal) never be used for drinking, cooking or (especially) baby formula.

Cross-linked polyethylene (PEX) piping, on the other hand, is flexible, smoother, does not scale or corrode, is resistant to acids, and is relatively resistant to frost-breakage. Because it comes in long spools, it has far fewer fittings (usually just one at each end) to leak or cause turbulence, and requires no solder or torch fuels. Because it is far simpler to install, it can typically be done less expensively, even with the now-common “home run” system in which each hot and cold fixture gets supplied by a separate pipe, allowing the use of smaller-diameter tubing, eliminating the pressure-drop common in most homes and allowing a centrally-located “switch panel” to isolate each fixture.

PEX has been used in Europe since the 60’s and in the US since the 80’s. It’s made from a petrochemical plastic and, while it has 46% more embodied energy per pound than copper, because it is so much less dense (lighter) it has 85% less embodied energy per unit volume.

Copper smelting and production also creates environmental emissions which cause both human toxicity and environmental impacts. PEX has recently been approved, after an extensive Environmental Impact Study, by the plastic-phobic state of California for all water supply systems, concluding that it would be “an environmentally superior action with respect to public health and hazards, water quality and air quality.” It is accepted by all North American plumbing codes. However, see the lawsuit below to overturn the California approval.

Copper ingestion is now associated with flu-like symptoms, kidney damage, Wilson’s disease, learning deficiencies in adolescents, and Alzheimer’s disease. It is not known whether it is carcinogenic.

Coalition of Environmental, Consumer, Public Health and Labor Organizations Have Filed Lawsuit to Overturn the Schwarzenegger Administration’s Approval of PEX Pipe

On February 19, 2009, a coalition including: (1) the Consumer Federation of California; (2) Planning and Conservation League; (3) Center for Environmental Health; (4) Sierra Club California; (5) California Professional Firefighters; and (6) the California State Pipe Trades Council jointly filed a lawsuit to overturn the Commission’s approval of PEX on the grounds that it was based upon a legally inadequate environmental impact report (EIR).

Potential Environmental, Health and Economic Risks Posed by PEX

Contamination of drinking water

The PEX EIR found that methyl tertiary-butyl ether (MTBE) and tert-Butyl alcohol can leach from PEX in amounts that exceed taste, odor and health guidelines set by the State of California for drinking water. The PEX EIR found that PEX pipes can initially leach as much as 290 ppb of MTBE. The California Department of Public Health and the California Office of Health Hazard Assessment have established a drinking water taste and odor standard of 5 ppb for MTBE and a drinking water public health goal and maximum contaminant level of 13 ppb.

The PEX EIR also found that PEX can leach ethyl tertiary butyl ether (ETBE), a chemical in the same family as MTBE, in amounts exceeding 100 ppb. An expert toxicologist report commissioned as part of the PEX EIR found that the leaching of ETBE from PEX pipe could contribute to taste and odor impacts, and could potentially lead to adverse health effects.

The PEX EIR found that PEX pipe is susceptible to permeation by outside contaminants such as pesticides, oil, gasoline, benzene and termiticides.

Numerous studies and articles submitted to the State of California comparing potable water pipe materials, including variants of PEX, polybutylene, polypropylene, CPVC, copper and steel, have found that PEX displayed the strongest biofilm formation and the strongest initial promotion of the growth of Legionella bacteria.

California’s January 2009 approval of PEX relies upon the less-protective PEX chlorine resistance standard ASTM F2023, instead of the much superior NSF P171 standard. ASTM F2023 only assures an adjusted lifetime of 25 years, while the NSF P171 standard assures a 40 year adjusted lifetime. At least one reputable PEX manufacturer (Lubrizol Advanced Materials, Inc.) has questioned the adequacy of this standard since it only results in “an expected service life of 25 years, five years less than the traditional home loan.”

Even short term exposure to sunlight can dramatically reduce the resistance of PEX to chlorine and result in premature rupture of the pipe. Studies show just a one-week exposure to sunlight may reduce the chlorine resistance lifetime of some PEX pipes by half; with a two week exposure completely depleting PEX of any chlorine resistance.

Lack of Recyclability

Because it is a thermoset plastic, PEX cannot be melted down and reused. A 2005 report by the San Francisco Department of the Environment found that PEX was the only type of plastic piping that no plastic recycler would accept. Copper pipe generally contains around 70% recycled material and has almost a 100% recycling rate.

Toxic Smoke

PEX produces toxic smoke when burned in building fires.

Testing and Certification

PEX-c is cross-linked in a cold process using electron beams rather than the heat and chemical based process for PEX-a or PEX-b, and is the cleanest of the three. PEX tubing meeting the health effects requirements of NSF/ANSI Standard 61 will bear either the NSF-61 mark or the NSF pw (potable water) mark on the print string. The NSF pw Mark indicates the product meets health requirements as well as performance, long term strength and quality control requirements.

Water exposed to PEX tubing and associated fitting systems are tested for the following contaminants as required by NSF/ANSI Standard 61:

  • VOCs (Volatile Organic Compounds)
  • Semi-volatile compounds
  • Phenolics
  • Regulated Metals including antimony, arsenic, barium, beryllium, cadmium, chromium, copper, lead, mercury, selenium, and thallium
  • Methanol
  • Tertiary butyl alcohol
  • MTBE (methyl tertiary butyl ether)
  • Any other potential contaminant identified during the formulation review.

These test methods are capable of detecting contaminants in water as low as 4 parts per billion.

ANSWERED BY RIVERSONG
Posted Wed, 02/17/2010 – 22:25

Note: there are mentions in blogs about plant based alternatives for plastics, HDPE from Brazillian sugarcane, and plant based plastics and polimers from hemp, Honesty, Castor and Meadowfern.

Polyethylene Pipe and Fittings (ref: www.iplex.com.au)

Material Properties

Terms frequently used to describe this material when used for engineering applications are high density (HDPE), medium density (MDPE) and most recently high performance (HPPE) polyethylene. Others PE types, such as low density (LDPE) and linear low density (LLDPE) are sometimes used for irrigation pipelines.

The Type 50 PE of AS1159 that was in common use until 1994, is an HDPE with a long-term design stress of 5.0 MPa. AS/NZS4130 and AS/NZS allow for three specific classifications by material strengths and sub classifications by performance at elevated temperatures.

The higher strength PE 80B and PE100 compounds are sometimes referred to as second and third generation materials. They were introduced into general service in the late seventies and early nineties respectively.

POLIplex polyethylene is an integrated family of PE pipes produced by Iplex , based on PE 80B, PE 80C and PE100 materials. PE80B material has 50-year design strength of 8 MPa whilst PE100 material’s minimum required strength is 10 MPa. Iplex POLIplex pipes are manufactured to AS/NZS 4130 from polyethylene’s complying with AS/NZS 4131.

PE Material Type               PE80B    PE100

MRS (50 year)     8 MPa    10 MPa

Flexural Yield Strength  27MPa  32 MPa

Circumferential Flexural Modulus (3 minute)     700 MPa                950 MPa

Circumferential Flexural Creep Modulus (50 year)           200 MPa                260 MPa

Density                  943 kg/m3            955 kg/m3

Tensile Yield Stress (50mm/min)               20 MPa                   25 MPa

Tensile Yield Strain (50mm/min)                8%           10%

Tensile Modulus                650 MPa                900 MPa

Poisson’s Ratio                   0.4           0.4

Thermal Expansion Coefficient 0.2 mm/m K        0.18 mm/m K

Thermal Conductivity    0.38 W/m K         0.38 W/m K

Material Composition

The polyethylene compounds used in POLIplex pipes and fittings are pre-compounded resins, either black or coloured with pigment, complying with AS/NZS 4131.

The following additives, if used, are added to the PE polymer base resin during the compounding process by the raw material manufacturer.

Anti-oxidants are used to inhibit oxidation of the polymer at the compounding stage and during subsequent processing. The oxidation induction test is an indicator of the efficacy of this additive and the residual amount after processing.

Carbon black is used in all black POLIplex pipe at a concentration of 2.25 ± 0.25% by mass as an ultra violet radiation absorber.

In natural and coloured PE materials, chemical ultra violet absorbers are used in lieu of carbon black.

Chrome Plating

Chrome plating is a hazardous process and as such is heavily regulated. Lead Chromates and Barium Sulphate are two of the hazardous waste products of its production. Un unfinished Brass finish requires more labour to achieve an attractive product but negates use of harmful processes.

Copper Poisoning Linked to Plastic Water Tanks

Copper in Drinking Water – Department of Public Health, Western Australia

Guidance on Use of Rainwater Tanks (PDF 979KB)